Type: | Sensor |
---|---|
Installation Mode: | Handheld |
Certification: | E-MARK, CE, ISO |
Suppliers with verified business licenses
Measurement item | Measuring range | precision | Resolution |
Wind speed | 0.6-40 m/s | Plus or minus 3% | 0.1 m/s |
Air temperature | - 29 ºC to 70 ºC | 0.5 ºC | 0.1 ºC |
Relative humidity | 10-90% | Plus or minus 2% | 0.1 |
stress | 700~1100hPa | 1.5 hPa/mb | 0.1 hPa/mb |
Wind direction | 0 to 360° | Plus or minus 5 ° | 1 ° |
Calculation item | Influencing factor | precision | Resolution |
Crosswind, headwind, downwind | Wind speed, orientation | 7.1% | 0.1m/s |
Altitude | Pressure, reference air pressure | 7.2m | 1m |
Atmospheric pressure | Pressure, reference altitude | 2.4hPa | 0.1hPa |
Wind chill | Wind speed, air temperature | 0.9ºC | 0.1ºC |
Thermal index | Temperature, relative humidity | 4ºC | 0.1ºC |
Dew point temperature | Temperature, relative humidity | 1.9ºC | 0.1ºC |
Wet bulb temperature | Temperature, relative humidity, pressure | 1.8ºC | 0.1ºC |
Density height | Temperature, relative humidity, pressure | 69m | 1m |
Automatic storage interval | 2 seconds --12 hours | ||
Data storage | >10000 groups | ||
Storage temperature | -30ºC ~ 60ºC | ||
Wireless transmission distance | 30 m (5700LINK) | ||
LCD and battery temperature | -10ºC to 55ºC | ||
Power source | 1 AA battery for approximately 400 hours | ||
Class of protection | IP67 | ||
Size/Weight | 127*45*28mm, 121g |